Greenville, SC, Commercial Air Leakage Testing
Greenville’s Upstate construction market moves fast. New medical campuses, manufacturing support buildings, and institutional projects are rising across the I-85 corridor, and each one needs a verified envelope before final sign-off. At Air Tight Solutions, our commercial air leakage testing in Greenville, SC, gives general contractors, owners, and commissioning agents actionable field data. We bring calibrated multi-fan rigs, certified technicians, and reports built for code review. Your schools, clinics, offices, and light industrial buildings get a verified envelope, and your schedule stays on track.
Schedule Your Test Now!
Field-Verified
Schedule-Friendly
Fully Documented
ASTM E779 Testing in Greenville for Larger Buildings
Every whole-building test we run follows recognized methods. Our ASTM E779 testing in Greenville measures airflow across a range of pressures. ASTM E1827 gives a faster option for smaller zones and compartmentalized spaces. You get a leakage rate tied to your spec, plus notes on where air escapes. That helps your team fix issues with confidence before turnover.
Reports Built for Institutional Review
Commercial buildings face strict review. Our commercial air leakage testing in Greenville, SC, delivers test pressures, flow data, and calculated results in one clear package. Designers, owners, and code officials can read it without extra back-and-forth.
Scheduled Around Upstate Weather
Spring storms, winter cold snaps, and gusty fronts can skew pressure readings. We watch the forecast and book commercial blower door testing in Greenville on calm, stable days. That protects your results and reduces the risk of a costly retest.
In Step With Your Commissioning Plan
Commissioning agents need envelope data at the right milestone. We time building envelope testing in Greenville, SC, with your Cx schedule, from mockup checks to final whole-building runs. Findings reach your team fast so that crews can seal gaps before ceilings close.
About Us
We didn’t start in a testing lab. Air Tight Solutions grew out of years spent on active construction sites, watching new homes take shape and seeing firsthand how much pressure builders and contractors faced to keep up with energy code requirements that were always shifting and rarely simple.
That experience made one thing clear: builders needed a partner who understood both the field and the code. So we built one. We redirected our know-how into energy efficiency testing and compliance services designed from the ground up for new construction only, with no detours into remodeling or retrofit work.
Affordable housing holds a special place in our work. Energy-efficient homes shouldn’t be limited to high-end projects, and we’ve made it a priority to help builders deliver sustainable, cost-effective housing to the communities that need it most. That commitment drives the same level of care on every site we test, regardless of project size or budget.
Air Tight Solutions continues to grow because that commitment holds on every project. Builders and developers across the Southeast trust us to show up on time, test with care, and hand over documentation that closes out cleanly. Quality, compliance, and sustainability aren’t goals we work toward. They’re the standard we start from.
Testimonials








Frequently Asked Questions
Not on every job. A whole-building air leakage test gets pulled into scope by the adopted commercial energy code, the ASHRAE 90.1 compliance path, LEED and other green programs, the owner’s or designer’s specifications, or a commissioning scope that lists it as a verification activity. In the Upstate, local AHJs handle plan review and final inspection, so the safest move is to identify your governing path and testing triggers during design, not during final inspection.
Our whole-building tests follow ASTM E779, which measures airflow across a range of pressures. ASTM E1827 gives a faster option for smaller zones and compartmentalized spaces, or when project conditions or the engineer’s specification call for the orifice method. For large multi-zone buildings where a single setup cannot pressurize the whole envelope, we apply ASTM E3158 sampling: tenant suites, floor zones or building sections are tested individually, and the results are aggregated per your project specifications.
In most cases, we can schedule your test for the very next business day once the building has power and all mechanical systems are fully installed. Because spring storms, winter cold snaps and gusty fronts can skew pressure readings, we watch the forecast and book commercial testing in Greenville on calm, stable days, which protects your results and reduces the risk of a costly retest.
The structure needs active power, and every mechanical system must be fully installed. Dampers, exhaust fans and other intentional openings should be ready for temporary sealing, so the test measures the envelope rather than the mechanical systems. We also recommend testing before drywall goes up: it catches leaks while they’re cheap and easy to seal.
You get test pressures, flow data and calculated results in one clear package, with ACH75 values and normalized leakage rates, formatted to match what your Cx package, AHJ submission or owner report requires. We do not pull permits, but the documentation we provide can be submitted directly to the county for final inspection.
Pricing depends on the size of the building, the scope of the test and the complexity of the work involved, so every project gets a customized quote. We offer free consultations to review your spec, leakage target and schedule, your quote includes the test itself and all required documentation, and we discuss all costs openly before any work begins.
A failed test points to specific leaks you can seal, and most fixes are targeted repairs rather than major rework, especially when issues are caught early. Leaks often turn up at roof-to-wall joints, penetrations and door frames. We don’t hand off a report and walk away: we review the results with you, point out likely leak sources, and help you plan a fast path to a passing retest.
Areas We Serve
The Upstate has become one of South Carolina’s busiest construction corridors, and our team keeps pace. We regularly schedule tests across Greenville, Spartanburg, Anderson, Greer, Simpsonville, Mauldin, and Easley, handling commercial air testing in Greenville County for everything from urgent care clinics to industrial support facilities along the BMW corridor. When projects take us further, we’re ready. Our reach extends into the rest of South Carolina, North Carolina, and Georgia, where builders count on the same certified process and clean documentation we deliver every time.