A bath fan can look perfect on the ceiling and still move half its rated airflow. On a multifamily job, that gap can show up at final and hold up a whole building. Crushed flex, stuck dampers, and wrong fan models usually cause the shortfall. Most of these issues stay hidden until someone measures them.
We created this guide to help developers and GCs plan exhaust fan CFM verification per ASHRAE 62.2 well before inspection day. You’ll learn what the standard asks for, how testers measure each fan, and why units come up short. We’ll also cover the paperwork your AHJ expects. Keep reading to turn ventilation testing into a simple checkbox.
ASHRAE 62.2 sets minimum ventilation rates for dwelling units, including units in multifamily buildings of any height. It also requires installers to measure airflow rather than trust the label. These four tips help your multifamily ventilation testing go smoothly.
For local exhaust, 62.2 calls for 50 CFM intermittent or 20 CFM continuous in bathrooms. Kitchens need a vented range hood at 100 CFM intermittent, or 5 air changes per hour continuously. Corridors and common areas usually follow ASHRAE 62.1 or the mechanical code. Confirm those design schedules early.
Accurate exhaust fan airflow measurement uses a calibrated flow hood, flow grid, or powered capture device. We test each fan at the grille with doors in their normal position. During bathroom exhaust CFM testing, we compare the measured number to the design value, not the box rating.
Most fans fail because of the duct, not the motor. Watch for:
Inspectors want clear proof. Each report should list the unit number, room, design CFM, measured CFM, test device, and test date. Clean records make ASHRAE 62.2 compliance multifamily reviews faster and cut repeat site visits.
Ventilation testing looks simple until you’re facing 200 units and a firm final date. A trained tester knows which fans provide whole-dwelling ventilation and which serve local exhaust. They also catch installation problems at rough-in, while ceilings are still open and fixes cost less.
Credentials matter. Look for BPI-certified techs who use calibrated gear and know the code edition your AHJ enforces. A pro can explain exhaust fan CFM verification and ASHRAE 62.2 results in plain words and tell your trades exactly what to fix. They’ll schedule around your phasing, test buildings as they release, and return fast for retests.
Pairing mechanical ventilation verification with blower door and duct testing saves trips, too. One team and one set of reports keep every building on track for occupancy.
Air Tight Solutions is a leading provider of energy efficiency testing and compliance services for new construction. Our certified team supports multifamily developers and GCs across South Carolina, North Carolina, and Georgia, with deep knowledge of IECC codes from 2009 to 2021.
We focus on what keeps your project moving. You get next-day scheduling, practical repair notes, and reports ready for county submission. Let’s make your next inspection a quick sign-off.
Bathrooms need 50 CFM intermittent or 20 CFM continuous exhaust. Always measure installed airflow, since field performance rarely matches the fan’s label rating.
Yes. Since the 2016 edition, 62.2 covers dwelling units in residential buildings of any height. Corridors and shared spaces typically fall under ASHRAE 62.1.
Long or crushed ducts, stuck dampers, blocked caps, and high static pressure cut airflow. The fan motor itself is rarely the real problem.
Spot-check at rough-in while ceilings are open. Then run final verification once fans, grilles, and terminations are fully installed and powered.
List the unit, room, design CFM, measured CFM, test device, and date. This gives your AHJ clear, consistent proof for final approval.